| Accelerated tests using the Larson-Miller formalism : the sample are pressurized up to maximum pressure of your application and placed into a oven. The temperature is raised far above the nominal temperature to accelerate the test. Thanks to the Larson-Miller law, the creep life of the heat exchanger can so be determined according your specification. | ||
![]() |
![]() |
![]() |